Mitsubishi Heavy Industries SRF25ZJX-S Specifications Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
24
Inverter Cooling Only
R410A
SRK-YJ
Wall Mounted type
SRC10YJ-S, SRC13YJ-S SRC18YJ-S
SRK10YJ-S
SRK13YJ-S
SRK18YJ-S
10m
15m
Maximum height difference
Maximum pipe length
Refrigerant pipe length
FUNCTION
Comfortable Functions
Convenient & Economy Functions
On Timer
24h Timer
Economy
DRY
OFF Timer
Sleep
Others
Restart
Auto
Back-up
Switch
24h ION
Luminous
Maintenance & Prevention Functions
Diagnostic
Self
Detachable
SUN
Filter
SUN
Filter
SUN
Filter
Comfortable Air Flow Functions
Auto Flap
Memory
UP/DOWN Lateral
Swing
Air Scroll
SRK10YJ-S, SRK13YJ-S, SRK18YJ-S
Enzyme
Filter
Enzyme
Filter
Enzyme
Filter
Auto
Indoor SRK10YJ-S SRK13YJ-S SRK18YJ-S
Outdoor SRC10YJ-S SRC13YJ-S SRC18YJ-S
Power Supply Outdoor Unit 1 Phase 230V 50Hz
Capacity Cooling T1 kW 2.50 3.50 5.00
Input Cooling T1 kW 0.70 0.99 1.56
Energy Label Cooling Stars 2.5 2 1.5
EER Cooling T1 3.57 3.54 3.21
Current
Cooling
Amp
3.4 4.5 7.1
Recommended Circuit Breaker 16
Sound Power Level (JIS C9612) Cooling Outdoor dB(A) 59 60 62
Air ow Cooling Indoor l/s 133 167 183
External Dimensions (HXWXD)
Indoor
mm
268x790x213
Outdoor 540x780(+62)x290 640x800(+71)x290
Net Weight
Indoor
kg
8.5
Outdoor 32 33 44
Refrigerant Piping
Liquid Line
mm
Ø6.35
Gas Line Ø9.52 Ø12.7
Connection Method Flare
Refrigerant R410A
Quantity kg 0.75 1.05 1.35
Pre Charged To Pipe Length m 10 15
Clean Filter Allergen Clear & Photocatalytic