2.4 Piping system
Models SRK20ZGX-S, 25ZGX-S, 35ZGX-S
Outdoor unitIndoor unit
Room temp.
sensor
Heat
exchanger
Flare connection
Heat
exchanger
sensor
Piping
(Liquid)
ø6.35
Check joint
4 way valve
Service valve (Liquid)
Flare connetion
Discharge pipe
temp. sensor
Cooling cycle
Heating cycle
Outdoor air
temp. sensor
Heat
exchanger
Heat exchanger
sensor
Compressor
Capillary tube
Strainer
Accumulator
Service valve
(Gas)
Electronic
expansion valve
Piping
(Gas)
ø9.52
Model SRK50ZGX-S
Outdoor unitIndoor unit
Room temp.
sensor
Heat
exchanger
Flare connection
Heat
exchanger
sensor
Piping
(Liquid)
ø6.35
Check joint
4 way valve
Service valve (Liquid)
Flare connection
Discharge pipe
temp. sensor
Cooling cycle
Heating cycle
Outdoor air
temp. sensor
Heat
exchanger
Heat exchanger
sensor
Compressor
Capillary tube
Strainer
Strainer
Service valve
(Gas)
Capillary tube
Electronic
expansion valve
Piping
(Gas)
ø12.7
Muffler
Capillary tube