Mitsubishi Heavy Industries SRK Series Specifications Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
-
14
-
4.4 Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong operation due to
mixed signals, please modify the printed circuit board in the indoor unit’s control box and the remote
control using the following procedure. Be sure to modify both boards. If only one board is modified,
receiving (and operation) cannot be done.
(1) Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (J6) using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the lead wires, etc.
(2) Modifying the wireless remote control
1) Remove the battery.
2) Cut the jumper wire shown in the figure at right.
Slant forward
blowing
HEAT
4.5 Flap and louver control
Control the flap and louver by AIRFLOW
(UP/DOWN) and
(LEFT/RIGHT) button on the wireless remote control.
(1) Swing flap
Flap moves in upward and downward directions continuously.
(2) Swing louver
Louver moves in left and right directions continuously.
(3) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(4) Memory flap (Flap or Louver stopped)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or louver is operating, it stops swinging
at an angle. Since this angle is memorized in the microcomputer, the flap or louver will automatically be set at this angle when the
next operation is started.
¡ Recommendable stopping angle of the flap
Horizontal
blowing
COOL•DRY
Cut
(2) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled as shown in the following chart with respect to the set temperature.
4.6 Timer operation
(1) Comfortable timer setting (ON timer)
(3) OFF timer operation
The Off timer can be set at a specific time (in 10-minute units) within a 24-hour period.
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto mode
operation is selected, the comfortable timer starts and determines the starting time of next operation based on the initial value of 15
minutes and the relationship between the room temperature at the setting time (temperature of room temperature sensor) and the
setting temperature.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 67 68

Comments to this Manuals

No comments