CAUTION
It is important that the following safety precautions be followed during installation of the air-conditioning equipment:
¡Do not place the air conditioner’s remote control unit in any location where it will be exposed to direct sunlight as this can cause the remote
control unit to be damaged or warped.
¡The equipment must be grounded; the ground wire should not be connected to either gas pipe, water pipe, lightning rod, or telephone ground
wires. Incorrect operation of the air conditioner or electric shocks can result if the grounding is not performed correctly.
¡An earth leakage breaker is required to be fitted in order to provide protection against the possibility of electric shocks, fires, and other similar
accidents.
¡Ensure that the air conditioner is securely installed in a location which is fully capable of supporting its weight. Failure to do so could result in a
number of different problems such as the unit toppling over and causing injury or generating increased operation noise due to vibration.
¡If there is a possibility that the in-door unit’s refrigerant concentration could exceed the threshold concentration (0.3 kg/m
3
) and result in
suffocation should a leakage of this gas occur, it will be necessary to provide an opening between the room containing the indoor unit and
neighboring rooms or to provide mechanical ventilating equipment which operates in response to gas leak warnings. Consult with staff at your
local sales outlet when purchasing such products.
Request
Please do not install and use the air-conditioning equipment in locations such as the following:
(1) In the vicinity of equipment which generates electromagnetic waves, such as that often found in hospitals, or in the vicinity of equipment
which generates high frequency waves: Installation in such locations is to be avoided as the generation of electromagnetic noise can cause
the controller to operate incorrectly.
(2) Areas which are exposed to salt air wind, such as coastal regions: Salt air can accelerate the corrosion of outer plating and the heat exchanger.
(3) Kitchens, machinery plants, and other similar locations where splashing and/or spraying of oil and grease occurs frequently or where a large
amount of heated air is present: Grease and hot air can easily enter and disrupt the operation of the indoor unit, and thus, the unit should not
be installed in such locations. In addition, these factors can also lead to reduced performance and/or corrosion of the heat exchanger as well
as resulting in damage to plastic parts.
(4) Any location where there is a possibility that corrosive gasses (sulfurous acid, etc.) or inflammable gasses (paint thinner vapor or gasoline
vapor, etc.) could be produced or could accumulate; also, installation and use of this air conditioner equipment in locations where volatile
inflammable substances are handled is to be avoided: These factors can lead to corrosion of the heat exchanger and to damage to plastic parts.
In addition, there is also a possibility that inflammable gasses could be ignited in the presence of the air-conditioner.
If spatter generated during welding and other similar operations comes into contact with the indoor unit, it may result in the unit being damaged.
Therefore, in addition to requesting that the utmost care be taken when performing this type of work in the vicinity of the air-conditioner
equipment, it is also requested that the unit be covered to prevent spatter from passing to its interior.
¡ Install the indoor securely in a location
which is fully capable of supporting its
weight. Installing in a location which is
not sufficiently reinforced or supported
may result in the indoor unit toppling and
falling, resulting in damage or injury.
Request
¡ It is important that enough space is
provided for performing maintenance
operations.
Request
Obtain the consent of the customer to
install the indoor unit in a location
which satisfies the following condi-
tions:
¡ Warm and cold air must be able to
dissipate freely.
¡ It must be possible to easily
connect wiring and piping to the
outdoor.
¡ The installation of a drain must be
possible.
¡ The section of floor for installation
must be sufficiently reinforced.
¡ Direct sunlight must not fall on the
in-door unit.
¡ There must be no obstacles or
blockages in the vicinity of the
suction air and discharge air
openings.
¡ There must be no possibility of
faulty operation of a fire alarm, as
must there be no possibility of short
circuits.
WARNING
(1) Selection of a suitable installation location
(a) Installation space
The dimensions shown below are the minimum which must be available
for installation of the indoor unit.
Unit: mm
Service
space
50
1000
600
100
50
50
600
All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions
do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular
problems occur, the matter should be referred to Mitsubishi Heavy Industries, Ltd. through your local distributor.
NOTICE
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION
AND/OR PROPERTY DAMAGE.
WARNING
18.5.1 Installation of indoor unit
Page view 13